This document, and the content contained herein, is intended for customers, users and other persons with the operation and features of the covered Hegla products. While Hegla makes every effort to include accurate and useful information, it is not possible to anticipate or address every possible situation or to account for conditions at unknown locations or interactions with unknown systems or components. Therefor, these documents must be used only for informational purposes and used in conjunction with best practices and with due care. Hegla shall not be responsible for any injuries or losses that occur as a result of the information in this document. Moreover, as products and offerings change over time, the usefulness of the information in this document may become obsolete. It is the responsibility of the reader or consumer to ensure that the information contained herein is timely and reflects the current reality of Hegla products and offerings. Hegla disclaims any and all warranties regarding the information in this document.
***Read chapter 1 of your operators manual before undertaking any work in the area of the overhead crane or floor loader equipment.***
When in doubt please contact Hegla service before taking action (404) 763-9700
The MOVI-C® system provides the option of storing the application data set of the inverter and the data set of the safety option on the memory module in the inverter.
The following steps must be performed for the actual device replacement:
- Switch off the device to be replaced.
- Remove the plugged-in memory module from the device.
- Remove the pluggable safety key from the CS..A safety option.
- Replace the device (including MOVISAFE® CS..A safety option).
- Insert the memory module removed in step 2 back into the replaced device.
- Insert the safety key removed in step 3 back into the replaced safety option.
- Carry out a functional test. The checking of all parameters is omitted.
The inverter automatically detects the device replacement and loads the application data set into the MOVISAFE® CS..A safety option. The localized key data set on the pluggable safety key ensures that the correct application data set has been loaded. The MOVISAFE® CS..A safety option is then in the same state that it was in before the device replacement. This means that if the MOVISAFE® CS..A safety option was in the "Accepted" state before the device replacement, it will be in the "Accepted" state again after device replacement. In order to ensure correct connection of the sensors and actuators, a function test of the safety option is required in the case of automatic device replacement function.
INFORMATION
Check the referencing of the CSA31A after having replaced a MOVISAFE® CSA31A safety option.